Most people judge a duct clean by feel: the house seems cooler, the bedroom outlet seems stronger. That is useful, but it is also easy to second-guess a week later. Measuring air speed at the outlets gives you something firmer. We use a handheld anemometer, an instrument with a small fan or sensor that reads how fast air is moving across it. Held in the same spot at the same outlet, it lets us compare the system before we touch it with the system after we finish.
Readings are taken with the system on the same settings each time, so the comparison is fair. We note the figure for each outlet we measure, then repeat the exercise once cleaning and any balancing is done. You see where airflow improved, by roughly how much, and whether any outlet is still lagging. A run that stays weak after cleaning is often the clue that points us towards a crushed duct, a stuck damper or a disconnected join further back.
Not every outlet suits a reliable reading. Some diffuser shapes or tight ceiling spots make it hard to hold the instrument steadily. Where that happens we say so, rather than quoting a number we do not trust. Readings also give you a reference point for the future. Next time the system is cleaned, or if a room starts to feel weak again, you can compare new figures with the old ones and see whether the change is gradual build-up or something more sudden.